- ELECTRIC TRANSFORMER
- SWITCHGEAR
- PFI PLANT
- BUSBAR TRUNKING
- ATS & GIS PANLE
- RING MAIN UNIT
- ONLINE UPS
- GENERATOR
PFI (Power Factor Improvement) Plant: Power Factor of the system is degraded due to inductive load of different industries and big apartments.
Regency Power Limited manufacture PFI (Power Factor Improvement) Plant for improving the degraded Power Factor of the system. We have microprocessor based PFC (Power Factor Correction) relay up to 16 stages. The Capacitors we use are of different ratings (2.5, 5, 10, 20, 25, 50 KVAR…. etc) and corresponding Magnetic Contactor for suitable stepping of the Capacitor bank
BENEFITS
- Power Consumption Reduced
- Electricity Bills Reduced
- Electrical Energy Efficiency Improved
- Extra KVA Availability From The Existing Supply
- Voltage drop reductions in long cables
- Adequate ratings of busbar shall be fixed at the back part of the cubicle and capacitors, magnetic contactor etc., will be located at the middle part on a front faced mounting plate.
BASIC FUNTIONS
- The cubicle / panel board shall be painted finish with semi-texture spray quoting with color RAL 7032 which shall be resistant to petrol, paraffin alkali.
- The Power Factor Improvement Plant will be assembled as per the BS standard. 3 Phase, 415 / 240V, 50Hz, Automatic Operation by means of PFC Relay.
- Sheet steel clad, dust and vermin proof free standing, floor mounting type cubicle made of 16 SWG sheet steel having front hinged type door with door locked.
- Reactive power control Relays are microprocessor-based control relay for intelligent control of capacitor banks with control contacts.
PFI (Power Factor Improvement) Plant: Power Factor of the system is degraded due to inductive load of different industries and big apartments. Energypac manufacture PFI (Power Factor Improvement) Plant for improving the degraded Power Factor of the system. We have microprocessor based PFC (Power Factor Correction) relay up to 16 stages. The Capacitors we use are of different ratings (2.5, 5, 10, 20, 25, 50 KVAR…. etc) and corresponding Magnetic Contactor for suitable stepping of the Capacitor bank
BENEFITS
- Power Consumption Reduced
- Electricity Bills Reduced
- Electrical Energy Efficiency Improved
- Extra KVA Availability From The Existing Supply
- Voltage drop reductions in long cables
- Adequate ratings of busbar shall be fixed at the back part of the cubicle and capacitors, magnetic contactor etc., will be located at the middle part on a front faced mounting plate.
BASIC FUNCTIONS
- The cubicle / panel board shall be painted finish with semi-texture spray quoting with color RAL 7032 which shall be resistant to petrol, paraffin alkali.
- The Power Factor Improvement Plant will be assembled as per the BS standard. 3 Phase, 415 / 240V, 50Hz, Automatic Operation by means of PFC Relay.
- Sheet steel clad, dust and vermin proof free standing, floor mounting type cubicle made of 16 SWG sheet steel having front hinged type door with door locked.
- Reactive power control Relays are microprocessor-based control relay for intelligent control of capacitor banks with control contacts.